Best Above Ground Pool Pumps of 2022
Oct 05, 2023Manually Operated Directional Valves, DMG06
Aug 27, 2023Centrifugal Pump Market worth $51.5 billion by 2028
May 20, 2023Poisoned Water: How a Navy Ship Dumped Fuel and Sickened Its Own Crew
May 21, 2023Dealer update: Fendt, Manitou and Merlo make changes
Oct 04, 2023Automatic Ball Valve Ensures Pump Prime
A high-capacity Plast-O-Matic VBS200EPS-PV Vacuum Breaker is used to prevent implosion as the tank drains while the pump is operating. (Image source: Plast-O-Matic Valves, Inc.)
Unfortunately the check valve in the tank would not hold, and the inlet piping to the pump would constantly drain.
To resolve the problem, an emergency priming system was designed to automatically flood the inlet piping, creating a prime for the pump. Plant industrial water is taken into Plast-O-Matic ABVS100EPS-PV Air x Spring Actuated Ball Valve, which is opened by compressed air through an air solenoid valve. When the pipe is sufficiently flooded, a flow switch signals the solenoid to shut off the air supply and vent the actuator. As soon as the air is removed and the actuator is no longer pressurized, the spring return design causes the valve to close automatically.
Source: Plast-O-Matic Valves, Inc.